500-920 Training & Certification Get Latest Cisco Channel Partner Data Center Updated on Sep 02, 2021
Certification Training for 500-920 Exam Dumps Test Engine
NEW QUESTION 10
When server is booting from SAN, which command verifies the PLOGI sessions with the target?
- A. FCMap
- B. Lunmap
- C. Lunlist
- D. FCIist
Answer: C
NEW QUESTION 11
When booting up a Cisco UCS Server you want to see boot time diagnostic messages of the POST, what action is required for you to do so?
- A. Enable Quiet Boot on the Server's BIOS
- B. Disable Fast Boot on the Server's Service Profile
- C. Disable Fast Boot on the Server's BIOS
- D. Restart the Server
- E. Enable Quiet Boot on the Server's Service Profile
Answer: E
NEW QUESTION 12
Which statement regarding the UCS C-senes connectivity modes best describes connectivity options in a UCS Manager integrated environment?
- A. All UCS C-series servers in a single UCS Manager domain must share the same connectivity model
- B. UCS C-series servers may be connected with or without the use of Fabric Extenders (FEX) in environments running UCS Manager Software Release 2 2 or later
- C. UCS C-series servers must be connected to Fabric Interconnects using Fabric Extenders (FEX)
- D. UCS C-series servers may be connected to multiple UCS Manager domains at the same time
Answer: B
NEW QUESTION 13
What occurs that causes a Split Brain Issue with Fabric Interconnects?
- A. A quorum tie occurs that must be resolved by the SEEPROM
- B. The subordinate Fabric Interconnect detects heartbeat failure and declares itself primary
- C. Manage configuration changes made with UCS Manager
- D. Both cluster links fail
Answer: B
NEW QUESTION 14
What is the result of enabling the Core File Exporter in UCS Manager?
- A. A core dump file will be immediately created and transmitted using HTTP protocol
- B. A core dump must be remotely activated by Cisco TAC.
- C. A core dump will immediately be generated and will be exported
- D. If a subsequent triggering event occurs, a core dump will be generated and sent by TFTP
Answer: C
NEW QUESTION 15
When troubleshooting, which option is the primary uses of the SCOPE command?
- A. To access the log files that reside in a component
- B. To access the log files on the virtual machines
- C. To access the log files on the log server
- D. The SCOPE command is not helpful in this case
Answer: A
NEW QUESTION 16
A Hard Drive (HDD) has been hot swapped in a UCS server blade, however, the UCS Manager GUI is not displaying updated metrics about the replacement drive. What action will be required to properly display updated metrics?
- A. Remove and re-insert the server blade HDD controller mezzanine card
- B. Use the CLI, since HDD metrics cannot be displayed with the UCS Manager GUI
- C. Reboot the server.
- D. Reboot the Fabric Interconnects
Answer: A
NEW QUESTION 17
Which two formats can be configured for Cisco's Call Home email message? (Choose two )
- A. JSON
- B. Full text
- C. CSV
- D. XML
Answer: B,D
Explanation:
Call Home Message Formats The Call Home feature offers the following message formats: * Short Text - Suitable for pagers or printed reports. * Plain Text - Full formatted message information suitable for human reading. * XML - Matching readable format using Extensible Markup Language (XML) and Adaptive Markup Language (AML) document type definitions (DTDs). The XML format enables communication with the Cisco TAC. For user-defined destination profiles, the format options are long-text, short-text, or XML. The default is XML. For the predefined Cisco TAC profile, only XML is allowed.
Reference:
http://www.audentia-gestion.fr/cisco/smart-call-home-feature-guide-1611.pdf
NEW QUESTION 18
If a Cisco UCS B-Series server fails to initialize, which method of access is required to troubleshoot?
- A. Use Cisco UCS Manager API to troubleshoot initialization
- B. Use direct console access to troubleshoot initialization
- C. Use KVM console to troubleshoot initialization
- D. Use Cisco UCS Manager GUI to troubleshoot initialization
Answer: C
NEW QUESTION 19
What is the likely cause of an intermittent SAN Boot fails?
- A. LUN ID Mismatch
- B. FCoE used instead of FC
- C. Misconfigured SAN boot target in the boot policy of the service profile
- D. Wrong boot order in the service profile
Answer: C
NEW QUESTION 20
The UCS Chassis Discovery Policy has been set to four and a new chassis is connected with two links What is the resulting chassis recognition action?
- A. The chassis will be recognized and both links will be active
- B. The chassis will be recognized but only one of the links will be active.
- C. The Chassis Discovery Policy will automatically reset to two links, since it always tracks the physical connections
- D. The chassis will not be recognized
Answer: D
NEW QUESTION 21
Which statement best describes managing Cisco UCS servers using NX-OS CLI on the Fabric Interconnects?
- A. The NX-OS CLI on the Fabric Interconnects allows you to change the connectivity configuration between the servers and Fabric Interconnects
- B. The NX-OS CLI on the Fabric Interconnects allows you to manage QoS parameters on the Fabric Interconnects and an upstream LAN switch
- C. The NX-OS CLI on the Fabric Interconnects allows you to change the connectivity configuration between the Fabric Interconnects and an upstream LAN switch.
- D. The NX-OS CLI on the Fabric Interconnects allows you to view, but not change the connectivity configuration between the Fabric Interconnects and an upstream LAN switch.
Answer: C
NEW QUESTION 22
When configuring UCS SAN Connectivity to a 3rd Party FibreChannel Storage Array that is connecting directly to the UCS Fabric Interconnects, which option is Cisco recommended'?
- A. Connect the Storage Array to a RC Storage Port and Enable NPV Mode on the UCS Fabric Interconnects
- B. Connect the Storage Array to an Appliance Port and Enable NPV Mode on the UCS Fabric Interconnects
- C. Direct connectivity between UCS Fabric Interconnects and FibreChannel Storage Arrays is not supported
- D. Connect the Storage Array to a FC Storage Port and Enable Switching Mode on the UCS Fabric Interconnects
- E. Connect the Storage Array to an Appliance Port and Enable Switching Mode on the UCS Fabric Interconnects
Answer: D
NEW QUESTION 23
Which ethernet port type is used when configuring UCS Fabric Interconnect connections to Cisco UCS C-series servers?
- A. Direct Connect Port
- B. Service Profile Port
- C. Server Port
- D. Uplink Port
Answer: D
NEW QUESTION 24
In order to create an Inband Profile for Cisco Integrated Management Controller (IMC) connectivity, what do you need to perform first?
- A. Create an IPMI Policy
- B. Create a Management IP Pool, a MAC Address Pool, and a VLAN Pool
- C. Create a Management IP Pool, a VLAN. and a VLAN Group
- D. Create a Service Profile
- E. Create different VLANs, with different VLAN IDs
Answer: D
NEW QUESTION 25
What three options should be verified, when you are able to connect to Cisco UCS Manager, but unable to open a KVM session to a blade? (Choose three)
- A. Verify the KVM IP Address is on the same subnet as the Fabric Interconnect management address
- B. Confirm the IP Address assigned to the KVM is not a duplicate IP
- C. Confirm the KVM IP Address is added to the route table in Cisco UCS Manager
- D. Confirm the IP Address assigned to UCS Manager is the same as the KVM address
- E. Verify TCP port 2068 is not blocked by an ACL or Firewall
- F. Verify the KVM IP Address is on the same ip subnet as the virtual machines
Answer: B,C,E
NEW QUESTION 26
......
Step by Step Guide to Prepare for 500-920 Exam: https://www.actualvce.com/Cisco/500-920-valid-vce-dumps.html