NEW QUESTION 10
When server is booting from SAN, which command verifies the PLOGI sessions with the target?

  • A. FCMap
  • B. Lunmap
  • C. Lunlist
  • D. FCIist

Answer: C

 

NEW QUESTION 11
When booting up a Cisco UCS Server you want to see boot time diagnostic messages of the POST, what action is required for you to do so?

  • A. Enable Quiet Boot on the Server's BIOS
  • B. Disable Fast Boot on the Server's Service Profile
  • C. Disable Fast Boot on the Server's BIOS
  • D. Restart the Server
  • E. Enable Quiet Boot on the Server's Service Profile

Answer: E

 

NEW QUESTION 12
Which statement regarding the UCS C-senes connectivity modes best describes connectivity options in a UCS Manager integrated environment?

  • A. All UCS C-series servers in a single UCS Manager domain must share the same connectivity model
  • B. UCS C-series servers may be connected with or without the use of Fabric Extenders (FEX) in environments running UCS Manager Software Release 2 2 or later
  • C. UCS C-series servers must be connected to Fabric Interconnects using Fabric Extenders (FEX)
  • D. UCS C-series servers may be connected to multiple UCS Manager domains at the same time

Answer: B

 

NEW QUESTION 13
What occurs that causes a Split Brain Issue with Fabric Interconnects?

  • A. A quorum tie occurs that must be resolved by the SEEPROM
  • B. The subordinate Fabric Interconnect detects heartbeat failure and declares itself primary
  • C. Manage configuration changes made with UCS Manager
  • D. Both cluster links fail

Answer: B

 

NEW QUESTION 14
What is the result of enabling the Core File Exporter in UCS Manager?

  • A. A core dump file will be immediately created and transmitted using HTTP protocol
  • B. A core dump must be remotely activated by Cisco TAC.
  • C. A core dump will immediately be generated and will be exported
  • D. If a subsequent triggering event occurs, a core dump will be generated and sent by TFTP

Answer: C

 

NEW QUESTION 15
When troubleshooting, which option is the primary uses of the SCOPE command?

  • A. To access the log files that reside in a component
  • B. To access the log files on the virtual machines
  • C. To access the log files on the log server
  • D. The SCOPE command is not helpful in this case

Answer: A

 

NEW QUESTION 16
A Hard Drive (HDD) has been hot swapped in a UCS server blade, however, the UCS Manager GUI is not displaying updated metrics about the replacement drive. What action will be required to properly display updated metrics?

  • A. Remove and re-insert the server blade HDD controller mezzanine card
  • B. Use the CLI, since HDD metrics cannot be displayed with the UCS Manager GUI
  • C. Reboot the server.
  • D. Reboot the Fabric Interconnects

Answer: A

 

NEW QUESTION 17
Which two formats can be configured for Cisco's Call Home email message? (Choose two )

  • A. JSON
  • B. Full text
  • C. CSV
  • D. XML

Answer: B,D

Explanation:
Call Home Message Formats The Call Home feature offers the following message formats: * Short Text - Suitable for pagers or printed reports. * Plain Text - Full formatted message information suitable for human reading. * XML - Matching readable format using Extensible Markup Language (XML) and Adaptive Markup Language (AML) document type definitions (DTDs). The XML format enables communication with the Cisco TAC. For user-defined destination profiles, the format options are long-text, short-text, or XML. The default is XML. For the predefined Cisco TAC profile, only XML is allowed.
Reference:
http://www.audentia-gestion.fr/cisco/smart-call-home-feature-guide-1611.pdf

 

NEW QUESTION 18
If a Cisco UCS B-Series server fails to initialize, which method of access is required to troubleshoot?

  • A. Use Cisco UCS Manager API to troubleshoot initialization
  • B. Use direct console access to troubleshoot initialization
  • C. Use KVM console to troubleshoot initialization
  • D. Use Cisco UCS Manager GUI to troubleshoot initialization

Answer: C

 

NEW QUESTION 19
What is the likely cause of an intermittent SAN Boot fails?

  • A. LUN ID Mismatch
  • B. FCoE used instead of FC
  • C. Misconfigured SAN boot target in the boot policy of the service profile
  • D. Wrong boot order in the service profile

Answer: C

 

NEW QUESTION 20
The UCS Chassis Discovery Policy has been set to four and a new chassis is connected with two links What is the resulting chassis recognition action?

  • A. The chassis will be recognized and both links will be active
  • B. The chassis will be recognized but only one of the links will be active.
  • C. The Chassis Discovery Policy will automatically reset to two links, since it always tracks the physical connections
  • D. The chassis will not be recognized

Answer: D

 

NEW QUESTION 21
Which statement best describes managing Cisco UCS servers using NX-OS CLI on the Fabric Interconnects?

  • A. The NX-OS CLI on the Fabric Interconnects allows you to change the connectivity configuration between the servers and Fabric Interconnects
  • B. The NX-OS CLI on the Fabric Interconnects allows you to manage QoS parameters on the Fabric Interconnects and an upstream LAN switch
  • C. The NX-OS CLI on the Fabric Interconnects allows you to change the connectivity configuration between the Fabric Interconnects and an upstream LAN switch.
  • D. The NX-OS CLI on the Fabric Interconnects allows you to view, but not change the connectivity configuration between the Fabric Interconnects and an upstream LAN switch.

Answer: C

 

NEW QUESTION 22
When configuring UCS SAN Connectivity to a 3rd Party FibreChannel Storage Array that is connecting directly to the UCS Fabric Interconnects, which option is Cisco recommended'?

  • A. Connect the Storage Array to a RC Storage Port and Enable NPV Mode on the UCS Fabric Interconnects
  • B. Connect the Storage Array to an Appliance Port and Enable NPV Mode on the UCS Fabric Interconnects
  • C. Direct connectivity between UCS Fabric Interconnects and FibreChannel Storage Arrays is not supported
  • D. Connect the Storage Array to a FC Storage Port and Enable Switching Mode on the UCS Fabric Interconnects
  • E. Connect the Storage Array to an Appliance Port and Enable Switching Mode on the UCS Fabric Interconnects

Answer: D

 

NEW QUESTION 23
Which ethernet port type is used when configuring UCS Fabric Interconnect connections to Cisco UCS C-series servers?

  • A. Direct Connect Port
  • B. Service Profile Port
  • C. Server Port
  • D. Uplink Port

Answer: D

 

NEW QUESTION 24
In order to create an Inband Profile for Cisco Integrated Management Controller (IMC) connectivity, what do you need to perform first?

  • A. Create an IPMI Policy
  • B. Create a Management IP Pool, a MAC Address Pool, and a VLAN Pool
  • C. Create a Management IP Pool, a VLAN. and a VLAN Group
  • D. Create a Service Profile
  • E. Create different VLANs, with different VLAN IDs

Answer: D

 

NEW QUESTION 25
What three options should be verified, when you are able to connect to Cisco UCS Manager, but unable to open a KVM session to a blade? (Choose three)

  • A. Verify the KVM IP Address is on the same subnet as the Fabric Interconnect management address
  • B. Confirm the IP Address assigned to the KVM is not a duplicate IP
  • C. Confirm the KVM IP Address is added to the route table in Cisco UCS Manager
  • D. Confirm the IP Address assigned to UCS Manager is the same as the KVM address
  • E. Verify TCP port 2068 is not blocked by an ACL or Firewall
  • F. Verify the KVM IP Address is on the same ip subnet as the virtual machines

Answer: B,C,E

 