Updated Oct 02, 2022 Verified DES-4122 dumps Q&As - 100% Pass
New 2022 Latest Questions DES-4122 Dumps - Use Updated EMC Exam
NEW QUESTION 34
An engineer wants to fully leverage Microsoft Windows Server 2016 for TPM-based guarded host deployment of a 14G server Which BIOS settings need to be used for installing the Windows server?
A)
B)
C)
D)
- A. Option A
- B. Option C
- C. Option D
- D. Option B
Answer: B
NEW QUESTION 35
A technician is sent on-site to troubleshoot a server that produced an error message during the most recent POST, but then completed the POST and booted to the operating system. The user cannot remember the specific error and no entry was made in the error log relating to this error.
How can the technician find out what the error message was?
- A. Reload the BIOS firmware
- B. Access the Lifecycle Controller and view the last boot cycle video capture entry
- C. Access the iDRAC and view the last boot cycle video capture entry
- D. Export the Server profile and analyze for any POST errors
Answer: B
NEW QUESTION 36
Dell EMC PowerEdge 14G servers support which technology?
- A. Intel Boot Guard
- B. iDRAC8
- C. AMD GuardMI
- D. Quicksync 1.0
Answer: C
NEW QUESTION 37
An engineer needs to install an additional PSU on an existing, single PSU Dell EMC PowerEdge R740. They complete the initial installation and cabling procedures. They connect an AC cable and the power distribution unit produces normal AC output. The engineer checks power management and sees that the new PSU is in the Failed state.
What task should be completed to troubleshoot this issue?
- A. Verify the new PSU is the same type and wattage rating
- B. Confirm the System Input Power CAP is not set to Low
- C. Set the PSU AC redundancy to 1+1
- D. Set the PSU AC redundancy to 1+0
Answer: A
NEW QUESTION 38
What is a key feature introduced in OpenManage Mobile v2.0?
- A. Access SupportAssist reports
- B. Access a Virtual Console (VNC over SSH) securely
- C. Access iDRAC remotely
- D. Access servers remotely through OME
Answer: A
NEW QUESTION 39
A technician needs to update the IDRAC license on a Dell EMC PowerEdge R740 server from Express to Enterprise. The server has the following components:
* 2x CPUs
* 384 GB RAM
* 6x 1 TB drives
* 1x PSU
The server is connected to active AC, but it is powered down, and it needs to stay powered down No errors are presently displayed How can the technician upgrade the license?
- A. Power on the server, then connect to the iDRAC and upgrade iDRAC license before powering down the server
- B. Connect to the iDRAC GUI and upgrade the .DRAC license while the server .s powered down
- C. The license cannot be upgraded because the user will not allow the server to be powered on
- D. The license cannot be upgraded on a single PSU system
Answer: D
NEW QUESTION 40
You must configure a BOSS card with 2 x 120GB drives for a Dell EMC PowerEdge server. What is the only supported mode?
- A. RAID 5
- B. Non-RAID Mirroring
- C. RAID 1
- D. RAID 0
Answer: D
NEW QUESTION 41
A Dell EMC PowerEdge R740 server requires a vFlash SD card urgently. Additional vFlash Cards and components from other servers are available.
What is the recommended solution?
- A. Reuse an existing vFlash SD card from a 14G server
- B. Reuse an existing vFlash SD card from either a 13G or 14G server
- C. Use a configuration option to convert BOSS to a virtual vFlash
- D. Use a configuration option to convert an NVMe drive to a virtual vFlash
Answer: A
NEW QUESTION 42
A technician needs to repurpose a Dell EMC PowerEdge server. The server has dual processors with 18 cores each The OS only "sees" 24 threads in total.
Which setting should the technician change in Processor Settings in the System BIOS?
- A. Virtualization Technology
- B. System Profile
- C. Number of Cores per Processor
- D. HyperThreading
Answer: B
NEW QUESTION 43
A technician wants to remotely log in to a server but finds that the IDRAC virtual Console feature Is not available. Use the simulator to explore the system. What Is the cause of this Issue?

Note: It is necessary to dose (x) the simulator window before you can select a response to this question.
- A. The Virtual Console is disabled
- B. Operating system not installed on remote server
- C. There are more than the maximum number of active sessions
- D. The server has been powered down
Answer: D
NEW QUESTION 44
A technician is creating a virtual disk in the iDRAC (2x 4 TB NL-SAS in RAID 1) to install Windows 2016 They manually boot to the OS installation media without using the Lifecycle Controller OS Deployment wizard Only the first 2048 GB on the virtual disk can be partitioned How should the technician obtain access to the remaining 2 TB (approximately) of storage?
- A. Use F2 to go into the BIOS, change the BIOS boot mode to UEFI, and try again
- B. Upgrade to a newer version of the operating system
- C. Delete the 4 TB virtual disk and create a virtual (boot) disk no larger than 2048 GB
- D. Use the Lifecycle Controller OS Deployment Wizard to deploy the OS on this server
Answer: B
NEW QUESTION 45
Which processor configuration is used by the Dell EMC PowerEdge R740 server?
- A. 2 socket AMD
- B. 4 socket Intel
- C. 2 socket Intel
- D. 4 socket AMD
Answer: C
NEW QUESTION 46
How can the ePSA be accessed?
- A. VMware vSphere plug-in
- B. Lifecycle Controller
- C. OMSA
- D. iDRAC
Answer: D
NEW QUESTION 47
What is a requirement to operate GPUs in a Dell EMC PowerEdge R740 server?
- A. All GPU cards must be of the same type and model
- B. All GPU cards must be installed on the same riser card.
- C. All GPU cards must be installed at the same time
- D. All GPU cards must be of the same type but can be a different model
Answer: C
NEW QUESTION 48
How can a technician know whether IDRAC9 System Lockdown mode is enabled?
- A. Lockdown activation message in yellow box in the iDRAC web GUI Access to LCC is disabled when the server boots
- B. Lockdown activation message in yellow box in the iDRAC web GUI Access to LCC requires a password when the server boots
- C. Lockdown activation message in red box in the iDRAC web GUI Access to LCC requires a password when the server boots
- D. Lockdown activation message in red box in the iDRAC web GUI Access to LCC is disabled when the server boots
Answer: D
NEW QUESTION 49
A Dell EMC PowerEdge server has been updated with an LCC and iDRAC DUP to the latest firmware when performing a firmware rollback?
- A. The iDRAC cannot be rolled back and the LCC cannot be rolled back
- B. Both the iDRAC and the LCC can be rolled back
- C. The LCC can be rolled back; the iDRAC cannot be rolled back
- D. The iDRAC can be rolled back; the LCC cannot be rolled back
Answer: C
NEW QUESTION 50
An engineer is checking a newly delivered Dell EMC PowerEdge R640 server that will be deployed for a new database environment The inventory consists of:
The server power configuration will be set for gnd redundancy The management switch is 1000 Base-T and the top of rack switches 10Gb What additional component(s) is needed for this configuration?
- A. Dell Networking, cable, 40GbE (QSFP+) to 4 x 10GbE SFP+ passive copper breakout cable, 3 meters - qty 2
- B. C20 to C21, PDU style, 250 V, 16 Amp, 3 5 meters power cord - qty 2
- C. Hot-plug power supply, 750 W - qty 1
- D. Hot-plug power supply, 1100W - qty 1
Answer: B
NEW QUESTION 51
For a temporary migration task the CPU core count on the Dell EMC PowerEdge R640 server needs to be reduced to 8 because the installed application will not work due to license restrictions. Use the simulator to apply the change so the application can be installed.
When you have finished using the simulator, click Next.
Answer:
Explanation:
Send us your suggestion for this simulation task.
NEW QUESTION 52
A technician needs to change the iDRAC password on a Dell EMC PowerEdge 14G server in a lights-out datacenter. The be rebooted because it is in production. The iDRAC is configured with the default credentials How could the technician change the iDRAC password?
- A. iDRAC Web GUI
- B. OpenManage Server Administrator
- C. Virtual Console; press F2 after rebooting system
- D. SupportAssist Enterprise
Answer: D
NEW QUESTION 53
Refer to the exhibit.
Match each callout to the Dell EMC PowerEdge server model shown.
Answer:
Explanation:
NEW QUESTION 54
When does a customer require the Service Tag of the Dell EMC PowerEdge server?
- A. First time accessing the BIOS
- B. First time logging in to iDRAC
- C. Obtaining warranty information
- D. Activating the OS
Answer: B
NEW QUESTION 55
What is the correct order of steps taken during the BIOS/UEFI Recovery process?
Answer:
Explanation:
NEW QUESTION 56
......
Latest DES-4122 Exam Dumps EMC Exam from Training: https://www.actualvce.com/EMC/DES-4122-valid-vce-dumps.html